by Digital Lagoon | Jan 30, 2019
POSSIBLE CAUSE: Clogged pump.SOLUTION: Open pump and remove debris.POSSIBLE CAUSE: Clogged pump intake screen.SOLUTION: Clean screen.POSSIBLE CAUSE: Recirculation valve turned down.SOLUTION: Adjust recirculation valve.POSSIBLE CAUSE: Pump motor running...
by Digital Lagoon | Jan 30, 2019
POSSIBLE CAUSE: Tripped breaker.SOLUTION: Reset breaker.POSSIBLE CAUSE: Line Disconnect in OFF position.SOLUTION: Turn line Disconnect to ON position.POSSIBLE CAUSE: Blown fuses on transformer.SOLUTION: Check and replace blown fuse(s).
by Digital Lagoon | Jan 30, 2019
POSSIBLE CAUSE: Drain open.SOLUTION: Install overflow pipe.POSSIBLE CAUSE: Incoming water valves are closed.SOLUTION: Open both hot and cold incoming water valves.
by Digital Lagoon | Jan 30, 2019
POSSIBLE CAUSE: Hot or cold incoming water valves are closed.SOLUTION: Open both hot and cold incoming water valves.POSSIBLE CAUSE: Blender is out of adjustment.SOLUTION: Adjust setting of blender.POSSIBLE CAUSE: Incoming water connections.SOLUTION: Switch incoming...
by Digital Lagoon | Jan 30, 2019
POSSIBLE CAUSE: Overload tripped.SOLUTION: Wait for overload to reset and check for cause of overload to trip, i.e. debris in pump.POSSIBLE CAUSE: Contact or not energized.SOLUTION: Check contact or connections.